boiler AFE Facilities Marketplace
Wide range of high pressure applications with flow rates up to 300 GPM Designed for: Circulation of liquids without suspended solids Pressure boosting and water supply Agricultural and commercial irrigation systems Commercial washing systems Boiler feed and condensate return Water treatment Reverse osmosis and filtration systems Circulation of coolants such as glycol …
Get PriceJan 08, 2020 · The tables recommend that a boiler feed unit should be used on all boilers over 300,000 BTU. The boiler feed receiver then becomes the reservoir for the system. The net usable storage capacity of the boiler feed receiver should be between 10 and 20 minutes. The minimum capacity shown in the tables is 10 minutes.
Get PriceApr 07, 2019 · The feeder also comes with two additional orifices, one for a feed rate of 1 GPM, and the other for a feed rate of 4 GPM. WFE Water Feeder. If you're working with a very small replacement steam boiler – say, one rated at 125,000 Btu/hr. – you should use the 1 GPM orifice, which is good for boilers up to 250,000 Btu/hr.
Get PriceSeries WSC and WSS are water make-up supply units. Both units include a positive air-gap to eliminate the likelihood of backflow and possible contamination of city water supply. These units supply a detached, central, make-up supply reservoir for de-aerators, boiler feed units, process loads, cooling systems and towers.
Get PriceSeries CBEM units are designed for small boiler feed systems handling condensate from steam heating or process applications. Units include cast iron receivers elevated 24" (610 mm) above the floor, pumps, pump suction …
Get PriceThe Series 1575 provides continuous protection against a low water condition and satisfies pump control needs for commercial and industrial steam boilers. The 1575 compensates for rapidly changing water levels. It has adjustable burner and pump settings and powerful 1 Hp relays. Features and Benefits Primary low water fuel cut-off protection and pump control forRead more
Get PriceTotal unit responsibility with factory assembled and tested pumps, receivers and controls. Series VCMD is a combination vacuum and boiler feed unit that offers a wide selection of cast iron, steel, and underground boiler feed receivers in conjunction with the dependable water jet vacuum units. The vacuum unit can be mounted on the boiler feed unit to conserve floor space or be …
Get PriceFeatures and Benefits For boiler receiver tanks Float operated Proportional feed action Soft seat provides positive seal Seal between float chamber and valve chamber is not a positive seal Maximum water supply pressure 100 psi (7 kg/cm2) Maximum inlet water temperature 120°F (49°C) Maximum vessel pressure 35 psi (2.5 kg/cm2)
Get PriceSeries CBEM units are designed for small boiler feed systems handling condensate from steam heating or process applications. Units include cast iron receivers elevated 24" (610 mm) above the floor, pumps, pump suction isolation valves, make-up valve and overflow connection. The pumps are controlled by a dedicated pump control on the boiler
Get PriceGoulds Water Technology Pumps: Water supply from wells or minicipal water, pressure boosting submersible and surface water pumps for residential water applications. Sump, effluent, and sewage pumps for wastewater use. Irrigation and sprinkler pump units. Pumps to handle a wide range of filtration, pressure boosting, water supply and boiler feed applications in industrial …
Get PriceSeries WSC and WSS are water make-up supply units. Both units include a positive air-gap to eliminate the likelihood of backflow and possible contamination of city water supply. These units supply a detached, central, make-up supply reservoir for de-aerators, boiler feed units, process loads, cooling systems and towers.
Get PriceFeatures and Benefits For low pressure steam and hot water boilers larger than 5,000 sq. ft. (465m2) with hot or cold water feed Optional Features No. 2 switch Manual reset Float block Proportional feed action Model 53 can be field upgraded with a No. 2 switch to add low water cut-off function Maximum water supplyRead more
Get PriceBoiler Accessories and components are installed to increase the efficiency of the boiler. We offer burners, heat exchangers, economizers, deaerators, flow meters, surge tanks, steam accumulators, condensors, pumps and motor assemblies. We stock over $5 million in boilers, boiler accessories and boiler parts with 24-hour access to all equipment.
Get PriceBell & Gossett is a division of Xylem, a spin off of ITT Industries, and is a leading manufacturer of energy efficient pumps, valves, heat exchangers, and accessories for plumbing, wastewater, and HVAC — including steam and heat transfer — applications.
Get PriceFeatures and Benefits For commercial and industrial low or high pressure boiler applications For boilers of any steaming capacity Monel bellows provides corrosion resistance Snap action switches for high temperature service 1 Single pole, single throw switch for pump control 1 Single pole, double throw switch for low water Cut-off and alarm actuation Optional FeaturesRead more
Get PriceWide range of high pressure applications with flow rates up to 300 GPM Designed for: Circulation of liquids without suspended solids Pressure boosting and water supply Agricultural and commercial irrigation systems Commercial washing systems Boiler feed and condensate return Water treatment Reverse osmosis and filtration systems Circulation of coolants such as glycol …
Get PriceOct 30, 2019 · Hoffman B Series inverted Bucket Trap and H Series Float & Thermostatic Trap. If Natural Gas cost $1.27/therm. (US average June 2018 bls.gov) the money wasted due to the faulty trap becomes $11.82/hr. (9.31 * 1.27). If the boiler is operating 241 days/year. October 1st – May 1st 10 hours/day it becomes $28,486/year.
Get PriceFeatures and Benefits For low pressure steam boilers with cold water feed Eliminates necessity to manually add water to the boiler Can be used with mechanical or electronic low water cut-off controls Quick-change replaceable cartridge valve and strainer Manual feed button Model 101-A features a 120 VAC solenoid Model 101-A-24 features a 24 VAC solenoidRead more
Get PriceDomestic Pump Series CMED is offered for boiler feed systems up to 1895 BHP. The CMED offers a flexible solution for handling feed water. The CMED has a receiver elevated 30" from the floor that is available in Steel, Galvanized Steel, …
Get PriceBoiler Feed Series WSC. Series WSC and WSS are water make-up supply units. Both units include a positive air-gap to eliminate the likelihood of backflow and possible contamination of city water supply. These units supply a detached, central, make-up supply reservoir for de-aerators, boiler feed units, process loads, cooling systems and towers.
Get Pricelocal Xylem HVAC Representative for more details. iron, steel, and underground boiler feed receivers in conjunction with the dependable water jet vacuum units. The vacuum unit can be mounted on the boiler feed unit to conserve floor space or be furnished separately.
Get PriceDescription: Series N256 Bronze Feed Water Pressure Regulators are for use in commercial and residential hydronic heating systems to fill the boiler and piping system with water, and to maintain water pressure in the system at all times. It also provides
Get PriceThey are suitable for boiler feed applications, domestic use, industrial applications and as boosters for irrigating gardens. MTH T31 Series Regenerative Turbine Pumps The T31 Series close-coupled regenerative turbine pumps represent the most economical, high performance alternative for low flow (1/2 to 9 GPM) applications involving moderate to
Get PriceSeries CM units consist of a cast iron receiver, one or two pumps, automatic make-up valve, and overflow connection. Series CSM units include low inlet lightweight steel receivers, pumps, make-up valve and overflow connection. …
Get PriceFlows to 350 GPM and 800 feet TDH. Designed to handle a wide range of filtration, pressure boost, wash system and boiler feed applications. Since 1997, Xylem's Goulds Water Technology and CentriPro brands have been providing variable speed pump control solutions to its customers. The first product was the AQUAVAR® variable speed controller.
Get PriceUnit shall be a Hoffman Specialty Series WCS as manufactured by Xylem Morton Grove, IL. Model WSCKefidB and WCDSKefidB MA - 14 Gallon Steel 2DCC19 Model WCSKefidB and WCSKefidB Steel 2DCC18 Hoffman Specialty Series VBF Stock Boiler Feed Pumps
Get PriceSeries CM Boiler feed units for systems up to 600 BHP. Series CM units include low inlet durable cast iron receivers for maximum corrosion resistance. Series CSM units include low inlet lightweight steel receivers. Both are available in simplex or duplex configuration. The Series CM includes a float switch and solenoid valve with "Y" strainerRead more
Get PriceFeatures and Benefits Field-adjustable dwell-feed cycles Multi-color LED status indicator Manual feed button Hard-stop limit to minimize chances of flooding the boiler Compatible with all electronic & mechanical Low Water Cut-Offs Includes adapters for connection to 1/2" copper tubing Removable strainer (replace after cleaning) Maximum water pressure 150 psi (10.5 …
Get PriceInstallation/Operation Manuals. MM 315 Models 51, 51S and 53 Boiler Water Feeders Models 51-2, 51-S-2 and 53-2 Feeder Cut-Off Combinations. PDF. 3 MB. MM 704 No. 2 Switch For series 47, 247, 63, 51, and 53 water feeders to add the low water cut-off function. PDF.
Get PriceAvailable in 3500 RPM (Series C35) and 1750 RPM (Series C17) Capacities to 600 GPM (37.8 l/s) Pressures to 100 psi (690 kPa) Series WSC and WSS are water make-up supply units. Both units include a positive air-gap to eliminate the likelihood of backflow and possible contamination of city water supply. These units supply a detached, central, make-up supply reservoir for de …
Get PriceInstallation/Operation Manuals. MM 315 Models 51, 51S and 53 Boiler Water Feeders Models 51-2, 51-S-2 and 53-2 Feeder Cut-Off Combinations. PDF. 3 MB. MM 704 No. 2 Switch For series 47, 247, 63, 51, and 53 water feeders to add the low water cut-off function. PDF.
Get PriceSeries CBM units are designed for small boiler feed systems handling condensate from steam heating or process applications. Units include receivers, pumps, make-up valve and overflow connection. The pumps are controlled by a dedicated pump control on the boiler (available as optional) responding to water level change in the boiler.
Get PriceSeries CBM units are designed for small boiler feed systems handling condensate from steam heating or process applications. Units include receivers, pumps, make-up valve and overflow connection. The pumps are controlled by …
Get PriceSep 29, 2015 · Adding chemical treatment to boilers. Volume 2/ Issue 5/ September 2015. An engineer planning to specify a Domestic 75CBM22-85 BFU recently asked us if it's feasible to have a chemical feed pump come on at the same time as the make-up to the BFU. The chemicals wouldn't be pumped into the receiver, but instead added to the make-up water.
Get PriceBoiler Feed Series WSC. Make-up water supply unit for up to 600 GPM and up to 100 psi / Cast iron tank with 20-year warranty against corrosion. Literature. Boiler Feed & Condensate Handling : Boiler Feed Pumping and Feed Units.
Get PriceBoiler Feed Series CMU. Below grade boiler feed return units for systems up to 580 BHP. This unit includes an epoxy coated steel receiver designed for installations with low or below grade return lines. The receiver is sized for 10 minutes net storage to absorb surges in rate of condensate return.
Get PriceDec 05, 2018 · What follows is a series of answers to questions about boiler feedwater pump basics, why these pumps are important and more. Pumps & Systems: What is a boiler feedwater pump. John Morton: Industrial power generation is important, and demand is growing. And at the heart of any power station's pre-boiler system is the boiler feed pump.
Get PriceDomestic Series CMU™ boiler feed units These units consist of a cast iron or epoxy coated steel receiver, one or two pumps, and automatic float control. Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 us know how we are doing.
Get PriceSeries CM Boiler feed units for systems up to 600 BHP. Series CM units include low inlet durable cast iron receivers for maximum corrosion resistance. Series CSM units include low inlet lightweight steel receivers. Both are available in …
Get PriceDomestic Pump - Xylem Applied Water Systems - United States. Combination boiler feed and a vacuum-producing unit with a number of configuration options / Serves up to 975 boiler HP Boiler Feed Series WSC Make-up water supply unit for up to 600 GPM and up to 100 psi / Cast iron tank with 20-year warranty against corrosion. Learn More.
Get PriceFeatures and Benefits For commercial and industrial low or high pressure boiler applications For boilers of any steaming capacity Monel bellows provides corrosion resistance Snap action switches for high temperature service 1 Single pole, single throw switch for pump control 1 Single pole, double throw switch for low water Cut-off and alarm actuation Optional FeaturesRead more
Get PriceThe e-MP Series Multi-Stage, Radially Split Pump is designed as a safe, strong, and cost-effective solution to get the job done in nearly any high-pressure application. Ideal uses include pressure boosting, boiler feed, filtration, fluid transport, dewatering, and more. • Capacities up to 2,600 GPM • Heads up to 3,100 feet
Get PriceBoiler Horsepower Model Number BBBB CCC-- Boiler Feed DOD Pump Discharge Pressure 10 2.05— Receiver - 100 Style Example: 205 Boiler 5.0 — 335 CMED— Style of Boiler Feed Receiver 2'NPSH Pump(s) Vertical Style Horsepower 50 PSI Discharge Pressure Boiler Horsepower x 34.5 = Lbs/Hr Series CMED Boiler Feed Units STANDARD UNIT FEATURES.
Get PriceSeries CBEM units are designed for small boiler feed systems handling condensate from steam heating or process applications. Units include cast iron receivers elevated 24" (610 mm) above the floor, pumps, pump suction …
Get Price